A supercomputer is a computer with a high level of performance as compared to a general-purpose computer. The performance of a supercomputer is commonly measured in floating-point operations per second (FLOPS) instead of million instructions per second (MIPS). Since 2017, there are supercomputers which can perform over 1017 FLOPS (a hundred quadrillion FLOPS, 100 petaFLOPS or 100 PFLOPS).[3] Since November 2017, all of the world's fastest 500 supercomputers run Linux-based operating systems.[4] Additional research is being conducted in the United States, the European Union, Taiwan, Japan, and China to build faster, more powerful and technologically superior exascale supercomputers.[5]
Supercomputers play an important role in the field of computational science, and are used for a wide range of computationally intensive tasks in various fields, including quantum mechanics, weather forecasting, climate research, oil and gas exploration, molecular modeling (computing the structures and properties of chemical compounds, biological macromolecules, polymers, and crystals), and physical simulations (such as simulations of the early moments of the universe, airplane and spacecraft aerodynamics, the detonation of nuclear weapons, and nuclear fusion). They have been essential in the field of cryptanalysis.[6]
Supercomputers were introduced in the 1960s, and for several decades the fastest were made by Seymour Cray at Control Data Corporation (CDC), Cray Research and subsequent companies bearing his name or monogram. The first such machines were highly tuned conventional designs that ran faster than their more general-purpose contemporaries. Through the decade, increasing amounts of parallelism were added, with one to four processors being typical. In the 1970s, vector processors operating on large arrays of data came to dominate. A notable example is the highly successful Cray-1 of 1976. Vector computers remained the dominant design into the 1990s. From then until today, massively parallel supercomputers with tens of thousands of off-the-shelf processors became the norm.[7][8]
The US has long been the leader in the supercomputer field, first through Cray's almost uninterrupted dominance of the field, and later through a variety of technology companies. Japan made major strides in the field in the 1980s and 90s, with China becoming increasingly active in the field. As of June 2020, the fastest supercomputer on the TOP500 supercomputer list is Fugaku, in Japan, with a LINPACK benchmark score of 415 PFLOPS, followed by Summit, by around 266.7 PFLOPS.[9] The US has four of the top 10; China and Italy have two each, Switzerland has one.[9] In June 2018, all combined supercomputers on the list broke the 1 exaFLOPS mark.[10]
In 1960 UNIVAC built the Livermore Atomic Research Computer (LARC), today considered among the first supercomputers, for the US Navy Research and Development Center. It still used high-speed drum memory, rather than the newly emerging disk drive technology.[11] Also, among the first supercomputers was the IBM 7030 Stretch. The IBM 7030 was built by IBM for the Los Alamos National Laboratory, which in 1955 had requested a computer 100 times faster than any existing computer. The IBM 7030 used transistors, magnetic core memory, pipelined instructions, prefetched data through a memory controller and included pioneering random access disk drives. The IBM 7030 was completed in 1961 and despite not meeting the challenge of a hundredfold increase in performance, it was purchased by the Los Alamos National Laboratory. Customers in England and France also bought the computer, and it became the basis for the IBM 7950 Harvest, a supercomputer built for cryptanalysis.[12]
The third pioneering supercomputer project in the early 1960s was the Atlas at the University of Manchester, built by a team led by Tom Kilburn. He designed the Atlas to have memory space for up to a million words of 48 bits, but because magnetic storage with such a capacity was unaffordable, the actual core memory of the Atlas was only 16,000 words, with a drum providing memory for a further 96,000 words. The Atlas operating system swapped data in the form of pages between the magnetic core and the drum. The Atlas operating system also introduced time-sharing to supercomputing, so that more than one program could be executed on the supercomputer at any one time.[13] Atlas was a joint venture between Ferranti and the Manchester University and was designed to operate at processing speeds approaching one microsecond per instruction, about one million instructions per second.[14]
The CDC 6600, designed by Seymour Cray, was finished in 1964 and marked the transition from germanium to silicon transistors. Silicon transistors could run faster and the overheating problem was solved by introducing refrigeration to the supercomputer design.[15] Thus, the CDC6600 became the fastest computer in the world. Given that the 6600 outperformed all the other contemporary computers by about 10 times, it was dubbed a supercomputer and defined the supercomputing market, when one hundred computers were sold at $8 million each.[16][17][18][19]
Cray left CDC in 1972 to form his own company, Cray Research.[17] Four years after leaving CDC, Cray delivered the 80 MHz Cray-1 in 1976, which became one of the most successful supercomputers in history.[20][21] The Cray-2 was released in 1985. It had eight central processing units (CPUs), liquid cooling and the electronics coolant liquid fluorinert was pumped through the supercomputer architecture. It performed at 1.9 gigaFLOPS and was the world's second fastest after M-13 supercomputer in Moscow.[22]
The only computer to seriously challenge the Cray-1's performance in the 1970s was the ILLIAC IV. This machine was the first realized example of a true massively parallel computer, in which many processors worked together to solve different parts of a single larger problem. In contrast with the vector systems, which were designed to run a single stream of data as quickly as possible, in this concept, the computer instead feeds separate parts of the data to entirely different processors and then recombines the results. The ILLIAC's design was finalized in 1966 with 256 processors and offer speed up to 1 GFLOPS, compared to the 1970s Cray-1's peak of 250 MFLOPS. However, development problems led to only 64 processors being built, and the system could never operate faster than about 200 MFLOPS while being much larger and more complex than the Cray. Another problem was that writing software for the system was difficult, and getting peak performance from it was a matter of serious effort.
But the partial success of the ILLIAC IV was widely seen as pointing the way to the future of supercomputing. Cray argued against this, famously quipping that "If you were plowing a field, which would you rather use? Two strong oxen or 1024 chickens?"[23] But by the early 1980s, several teams were working on parallel designs with thousands of processors, notably the Connection Machine (CM) that developed from research at MIT. The CM-1 used as many as 65,536 simplified custom microprocessors connected together in a network to share data. Several updated versions followed; the CM-5 supercomputer is a massively parallel processing computer capable of many billions of arithmetic operations per second.[24]
In 1982, Osaka University's LINKS-1 Computer Graphics System used a massively parallel processing architecture, with 514 microprocessors, including 257 Zilog Z8001 control processors and 257 iAPX 86/20 floating-point processors. It was mainly used for rendering realistic 3D computer graphics.[25] Fujitsu's VPP500 from 1992 is unusual since, to achieve higher speeds, its processors used GaAs, a material normally reserved for microwave applications due to its toxicity.[26]Fujitsu's Numerical Wind Tunnel supercomputer used 166 vector processors to gain the top spot in 1994 with a peak speed of 1.7 gigaFLOPS (GFLOPS) per processor.[27][28] The Hitachi SR2201 obtained a peak performance of 600 GFLOPS in 1996 by using 2048 processors connected via a fast three-dimensional crossbar network.[29][30][31] The Intel Paragon could have 1000 to 4000 Intel i860 processors in various configurations and was ranked the fastest in the world in 1993. The Paragon was a MIMD machine which connected processors via a high speed two-dimensional mesh, allowing processes to execute on separate nodes, communicating via the Message Passing Interface.[32]
Software development remained a problem, but the CM series sparked off considerable research into this issue. Similar designs using custom hardware were made by many companies, including the Evans & Sutherland ES-1, MasPar, nCUBE, Intel iPSC and the Goodyear MPP. But by the mid-1990s, general-purpose CPU performance had improved so much in that a supercomputer could be built using them as the individual processing units, instead of using custom chips. By the turn of the 21st century, designs featuring tens of thousands of commodity CPUs were the norm, with later machines adding graphic units to the mix.[7][8]
Systems with a massive number of processors generally take one of two paths. In the grid computing approach, the processing power of many computers, organised as distributed, diverse administrative domains, is opportunistically used whenever a computer is available[33]and in another approach, many processors are used in proximity to each other, e.g. in a computer cluster. In such a centralized massively parallel system the speed and flexibility of the interconnect becomes very important and modern supercomputers have used various approaches ranging from enhanced Infiniband systems to three-dimensional torus interconnects.[34][35] The use of multi-core processors combined with centralization is an emerging direction, e.g. as in the Cyclops64 system.[36][37]
As the price, performance and energy efficiency of general purpose graphic processors (GPGPUs) have improved, a number of petaFLOPS supercomputers such as Tianhe-I and Nebulae have started to rely on them.[38] However, other systems such as the K computer continue to use conventional processors such as SPARC-based designs and the overall applicability of GPGPUs in general-purpose high-performance computing applications has been the subject of debate, in that while a GPGPU may be tuned to score well on specific benchmarks, its overall applicability to everyday algorithms may be limited unless significant effort is spent to tune the application to it.[39] However, GPUs are gaining ground and in 2012 the Jaguar supercomputer was transformed into Titan by retrofitting CPUs with GPUs.[40][41][42]
High-performance computers have an expected life cycle of about three years before requiring an upgrade.[43] The Gyoukou supercomputer is unique in that it uses both a massively parallel design and liquid immersion cooling.
A number of "special-purpose" systems have been designed, dedicated to a single problem. This allows the use of specially programmed FPGA chips or even custom ASICs, allowing better price/performance ratios by sacrificing generality. Examples of special-purpose supercomputers include Belle,[44]Deep Blue,[45] and Hydra,[46] for playing chess, Gravity Pipe for astrophysics,[47]MDGRAPE-3 for protein structure computation molecular dynamics[48] and Deep Crack,[49] for breaking the DES cipher.
Throughout the decades, the management of heat density has remained a key issue for most centralized supercomputers.[52][53][54] The large amount of heat generated by a system may also have other effects, e.g. reducing the lifetime of other system components.[55] There have been diverse approaches to heat management, from pumping Fluorinert through the system, to a hybrid liquid-air cooling system or air cooling with normal air conditioning temperatures.[56][57] A typical supercomputer consumes large amounts of electrical power, almost all of which is converted into heat, requiring cooling. For example, Tianhe-1A consumes 4.04 megawatts (MW) of electricity.[58] The cost to power and cool the system can be significant, e.g. 4 MW at $0.10/kWh is $400 an hour or about $3.5 million per year.
Heat management is a major issue in complex electronic devices and affects powerful computer systems in various ways.[59] The thermal design power and CPU power dissipation issues in supercomputing surpass those of traditional computer cooling technologies. The supercomputing awards for green computing reflect this issue.[60][61][62]
The packing of thousands of processors together inevitably generates significant amounts of heat density that need to be dealt with. The Cray 2 was liquid cooled, and used a Fluorinert "cooling waterfall" which was forced through the modules under pressure.[56] However, the submerged liquid cooling approach was not practical for the multi-cabinet systems based on off-the-shelf processors, and in System X a special cooling system that combined air conditioning with liquid cooling was developed in conjunction with the Liebert company.[57]
In the Blue Gene system, IBM deliberately used low power processors to deal with heat density.[63] The IBM Power 775, released in 2011, has closely packed elements that require water cooling.[64] The IBM Aquasar system uses hot water cooling to achieve energy efficiency, the water being used to heat buildings as well.[65][66]
The energy efficiency of computer systems is generally measured in terms of "FLOPS per watt". In 2008, Roadrunner by IBM operated at 3.76 MFLOPS/W.[67][68] In November 2010, the Blue Gene/Q reached 1,684 MFLOPS/W[69][70] and in June 2011 the top 2 spots on the Green 500 list were occupied by Blue Gene machines in New York (one achieving 2097 MFLOPS/W) with the DEGIMA cluster in Nagasaki placing third with 1375 MFLOPS/W.[71]
Because copper wires can transfer energy into a supercomputer with much higher power densities than forced air or circulating refrigerants can remove waste heat,[72] the ability of the cooling systems to remove waste heat is a limiting factor.[73][74] As of 2015[update], many existing supercomputers have more infrastructure capacity than the actual peak demand of the machine – designers generally conservatively design the power and cooling infrastructure to handle more than the theoretical peak electrical power consumed by the supercomputer. Designs for future supercomputers are power-limited – the thermal design power of the supercomputer as a whole, the amount that the power and cooling infrastructure can handle, is somewhat more than the expected normal power consumption, but less than the theoretical peak power consumption of the electronic hardware.[75]
Since the end of the 20th century, supercomputer operating systems have undergone major transformations, based on the changes in supercomputer architecture.[76] While early operating systems were custom tailored to each supercomputer to gain speed, the trend has been to move away from in-house operating systems to the adaptation of generic software such as Linux.[77]
Since modern massively parallel supercomputers typically separate computations from other services by using multiple types of nodes, they usually run different operating systems on different nodes, e.g. using a small and efficient lightweight kernel such as CNK or CNL on compute nodes, but a larger system such as a Linux-derivative on server and I/O nodes.[78][79][80]
While in a traditional multi-user computer system job scheduling is, in effect, a tasking problem for processing and peripheral resources, in a massively parallel system, the job management system needs to manage the allocation of both computational and communication resources, as well as gracefully deal with inevitable hardware failures when tens of thousands of processors are present.[81]
Although most modern supercomputers use a Linux-based operating system, each manufacturer has its own specific Linux-derivative, and no industry standard exists, partly due to the fact that the differences in hardware architectures require changes to optimize the operating system to each hardware design.[76][82]
The parallel architectures of supercomputers often dictate the use of special programming techniques to exploit their speed. Software tools for distributed processing include standard APIs such as MPI and PVM, VTL, and open source software such as Beowulf.
In the most common scenario, environments such as PVM and MPI for loosely connected clusters and OpenMP for tightly coordinated shared memory machines are used. Significant effort is required to optimize an algorithm for the interconnect characteristics of the machine it will be run on; the aim is to prevent any of the CPUs from wasting time waiting on data from other nodes. GPGPUs have hundreds of processor cores and are programmed using programming models such as CUDA or OpenCL.
Moreover, it is quite difficult to debug and test parallel programs. Special techniques need to be used for testing and debugging such applications.
Opportunistic Supercomputing is a form of networked grid computing whereby a "super virtual computer" of many loosely coupled volunteer computing machines performs very large computing tasks. Grid computing has been applied to a number of large-scale embarrassingly parallel problems that require supercomputing performance scales. However, basic grid and cloud computing approaches that rely on volunteer computing cannot handle traditional supercomputing tasks such as fluid dynamic simulations.[84]
The fastest grid computing system is the distributed computing project Folding@home (F@h). F@h reported 2.5 exaFLOPS of x86 processing power As of April 2020[update]. Of this, over 100 PFLOPS are contributed by clients running on various GPUs, and the rest from various CPU systems.[85]
The Berkeley Open Infrastructure for Network Computing (BOINC) platform hosts a number of distributed computing projects. As of February 2017[update], BOINC recorded a processing power of over 166 petaFLOPS through over 762 thousand active Computers (Hosts) on the network.[86]
As of October 2016[update], Great Internet Mersenne Prime Search's (GIMPS) distributed Mersenne Prime search achieved about 0.313 PFLOPS through over 1.3 million computers.[87] The Internet PrimeNet Server supports GIMPS's grid computing approach, one of the earliest and most successful[citation needed] grid computing projects, since 1997.
Quasi-opportunistic supercomputing is a form of distributed computing whereby the "super virtual computer" of many networked geographically disperse computers performs computing tasks that demand huge processing power.[88] Quasi-opportunistic supercomputing aims to provide a higher quality of service than opportunistic grid computing by achieving more control over the assignment of tasks to distributed resources and the use of intelligence about the availability and reliability of individual systems within the supercomputing network. However, quasi-opportunistic distributed execution of demanding parallel computing software in grids should be achieved through implementation of grid-wise allocation agreements, co-allocation subsystems, communication topology-aware allocation mechanisms, fault tolerant message passing libraries and data pre-conditioning.[88]
Cloud computing with its recent and rapid expansions and development have grabbed the attention of high-performance computing (HPC) users and developers in recent years. Cloud computing attempts to provide HPC-as-a-service exactly like other forms of services available in the cloud such as software as a service, platform as a service, and infrastructure as a service. HPC users may benefit from the cloud in different angles such as scalability, resources being on-demand, fast, and inexpensive. On the other hand, moving HPC applications have a set of challenges too. Good examples of such challenges are virtualization overhead in the cloud, multi-tenancy of resources, and network latency issues. Much research is currently being done to overcome these challenges and make HPC in the cloud a more realistic possibility.[89][90][91][92]
In 2016 Penguin Computing, R-HPC, Amazon Web Services, Univa, Silicon Graphics International, Sabalcore, and Gomput started to offer HPC cloud computing. The Penguin On Demand (POD) cloud is a bare-metal compute model to execute code, but each user is given virtualized login node. POD computing nodes are connected via non-virtualized 10 Gbit/s Ethernet or QDR InfiniBand networks. User connectivity to the POD data center ranges from 50 Mbit/s to 1 Gbit/s.[93] Citing Amazon's EC2 Elastic Compute Cloud, Penguin Computing argues that virtualization of compute nodes is not suitable for HPC. Penguin Computing has also criticized that HPC clouds may have allocated computing nodes to customers that are far apart, causing latency that impairs performance for some HPC applications.[94]
Supercomputers generally aim for the maximum in capability computing rather than capacity computing. Capability computing is typically thought of as using the maximum computing power to solve a single large problem in the shortest amount of time. Often a capability system is able to solve a problem of a size or complexity that no other computer can, e.g., a very complex weather simulation application.[95]
Capacity computing, in contrast, is typically thought of as using efficient cost-effective computing power to solve a few somewhat large problems or many small problems.[95] Architectures that lend themselves to supporting many users for routine everyday tasks may have a lot of capacity but are not typically considered supercomputers, given that they do not solve a single very complex problem.[95]
In general, the speed of supercomputers is measured and benchmarked in FLOPS ("floating-point operations per second"), and not in terms of MIPS ("million instructions per second), as is the case with general-purpose computers.[96] These measurements are commonly used with an SI prefix such as tera-, combined into the shorthand "TFLOPS" (1012 FLOPS, pronounced teraflops), or peta-, combined into the shorthand "PFLOPS" (1015 FLOPS, pronounced petaflops.) "Petascale" supercomputers can process one quadrillion (1015) (1000 trillion) FLOPS. Exascale is computing performance in the exaFLOPS (EFLOPS) range. An EFLOPS is one quintillion (1018) FLOPS (one million TFLOPS).
No single number can reflect the overall performance of a computer system, yet the goal of the Linpack benchmark is to approximate how fast the computer solves numerical problems and it is widely used in the industry.[97] The FLOPS measurement is either quoted based on the theoretical floating point performance of a processor (derived from manufacturer's processor specifications and shown as "Rpeak" in the TOP500 lists), which is generally unachievable when running real workloads, or the achievable throughput, derived from the LINPACK benchmarks and shown as "Rmax" in the TOP500 list.[98] The LINPACK benchmark typically performs LU decomposition of a large matrix.[99] The LINPACK performance gives some indication of performance for some real-world problems, but does not necessarily match the processing requirements of many other supercomputer workloads, which for example may require more memory bandwidth, or may require better integer computing performance, or may need a high performance I/O system to achieve high levels of performance.[97]
Since 1993, the fastest supercomputers have been ranked on the TOP500 list according to their LINPACK benchmark results. The list does not claim to be unbiased or definitive, but it is a widely cited current definition of the "fastest" supercomputer available at any given time.
This is a recent list of the computers which appeared at the top of the TOP500 list,[100] and the "Peak speed" is given as the "Rmax" rating. In 2018, Lenovo became the world's largest provider for the TOP500 supercomputers with 117 units produced.[101]
Year | Supercomputer | Rmax (TFlop/s) |
Location |
---|---|---|---|
2020 | Fujitsu Fugaku | 442,010.0 | Kobe, Japan |
2018 | IBM Summit | 148,600.0 | Oak Ridge, U.S. |
2018 | IBM/Nvidia/Mellanox Sierra | 94,640.0 | Livermore, U.S. |
2016 | Sunway TaihuLight | 93,014.6 | Wuxi, China |
2013 | NUDT Tianhe-2 | 61,444.5 | Guangzhou, China |
2019 | Dell Frontera | 23,516.4 | Austin, U.S. |
2012 | Cray/HPE Piz Daint | 21,230.0 | Lugano, Switzerland |
2015 | Cray/HPE Trinity | 20,158.7 | New Mexico, U.S. |
2018 | Fujitsu ABCI | 19,880.0 | Tokyo, Japan |
2018 | Lenovo SuperMUC-NG | 19,476.6 | Garching, Germany |
This section is in list format, but may read better as prose.(January 2020) |
This section needs expansion. You can help by adding to it. (January 2020) |
The stages of supercomputer application may be summarized in the following table:
Decade | Uses and computer involved |
---|---|
1970s | Weather forecasting, aerodynamic research (Cray-1).[102] |
1980s | Probabilistic analysis,[103] radiation shielding modeling[104] (CDC Cyber). |
1990s | Brute force code breaking (EFF DES cracker).[105] |
2000s | 3D nuclear test simulations as a substitute for legal conduct Nuclear Non-Proliferation Treaty (ASCI Q).[106] |
2010s | Molecular Dynamics Simulation (Tianhe-1A)[107] |
2020s | Scientific research for outbreak prevention/Electrochemical Reaction Research[108] |
The IBM Blue Gene/P computer has been used to simulate a number of artificial neurons equivalent to approximately one percent of a human cerebral cortex, containing 1.6 billion neurons with approximately 9 trillion connections. The same research group also succeeded in using a supercomputer to simulate a number of artificial neurons equivalent to the entirety of a rat's brain.[109]
Modern-day weather forecasting also relies on supercomputers. The National Oceanic and Atmospheric Administration uses supercomputers to crunch hundreds of millions of observations to help make weather forecasts more accurate.[110]
In 2011, the challenges and difficulties in pushing the envelope in supercomputing were underscored by IBM's abandonment of the Blue Waters petascale project.[111]
The Advanced Simulation and Computing Program currently uses supercomputers to maintain and simulate the United States nuclear stockpile.[112]
In early 2020, COVID-19 was front and center in the world. Supercomputers used different simulations to find compounds that could potentially stop the spread. These computers run for tens of hours using multiple paralleled running CPU's to model different processes.[113][114][115]
In the 2010s, China, the United States, the European Union, and others competed to be the first to create a 1 exaFLOP (1018 or one quintillion FLOPS) supercomputer.[116] Erik P. DeBenedictis of Sandia National Laboratories has theorized that a zettaFLOPS (1021 or one sextillion FLOPS) computer is required to accomplish full weather modeling, which could cover a two-week time span accurately.[117][118][119] Such systems might be built around 2030.[120]
Many Monte Carlo simulations use the same algorithm to process a randomly generated data set; particularly, integro-differential equations describing physical transport processes, the random paths, collisions, and energy and momentum depositions of neutrons, photons, ions, electrons, etc. The next step for microprocessors may be into the third dimension; and specializing to Monte Carlo, the many layers could be identical, simplifying the design and manufacture process.[121]
The cost of operating high performance supercomputers has risen, mainly due to increasing power consumption. In the mid 1990s a top 10 supercomputer required in the range of 100 kilowatts, in 2010 the top 10 supercomputers required between 1 and 2 megawatts.[122] A 2010 study commissioned by DARPA identified power consumption as the most pervasive challenge in achieving Exascale computing.[123] At the time a megawatt per year in energy consumption cost about 1 million dollars. Supercomputing facilities were constructed to efficiently remove the increasing amount of heat produced by modern multi-core central processing units. Based on the energy consumption of the Green 500 list of supercomputers between 2007 and 2011, a supercomputer with 1 exaflops in 2011 would have required nearly 500 megawatts. Operating systems were developed for existing hardware to conserve energy whenever possible.[124] CPU cores not in use during the execution of a parallelised application were put into low-power states, producing energy savings for some supercomputing applications.[125]
The increasing cost of operating supercomputers has been a driving factor in a trend toward bundling of resources through a distributed supercomputer infrastructure. National supercomputing centers first emerged in the US, followed by Germany and Japan. The European Union launched the Partnership for Advanced Computing in Europe (PRACE) with the aim of creating a persistent pan-European supercomputer infrastructure with services to support scientists across the European Union in porting, scaling and optimizing supercomputing applications.[122] Iceland built the world's first zero-emission supercomputer. Located at the Thor Data Center in Reykjavík, Iceland, this supercomputer relies on completely renewable sources for its power rather than fossil fuels. The colder climate also reduces the need for active cooling, making it one of the greenest facilities in the world of computers.[126]
Funding supercomputer hardware also became increasingly difficult. In the mid 1990s a top 10 supercomputer cost about 10 million Euros, while in 2010 the top 10 supercomputers required an investment of between 40 and 50 million Euros.[122] In the 2000s national governments put in place different strategies to fund supercomputers. In the UK the national government funded supercomputers entirely and high performance computing was put under the control of a national funding agency. Germany developed a mixed funding model, pooling local state funding and federal funding.[122]
Many science fiction writers have depicted supercomputers in their works, both before and after the historical construction of such computers. Much of such fiction deals with the relations of humans with the computers they build and with the possibility of conflict eventually developing between them. Examples of supercomputers in fiction include HAL-9000, Multivac, The Machine Stops, GLaDOS, The Evitable Conflict, Vulcan's Hammer, Colossus, WOPR, and Deep Thought.
performing 376 million calculations for every watt of electricity used.
IBM... BlueGene/Q system .. setting a record in power efficiency with a value of 1,680 MFLOPS/W, more than twice that of the next best system.
By: Wikipedia.org
Edited: 2021-06-18 15:15:08